AK Appleply Club Fire Defender — Fire Retardant Plywood (IS 5509 Certified)

AK Appleply Club – Fire Retardant Plywood (IS 5509 Certified)

AK Appleply Club is a reliable, code-compliant fire retardant plywood built for spaces where safety and longevity matter. Manufactured to meet IS 5509, it combines carefully selected hardwoods with proven manufacturing processes to slow flame spread, reduce smoke, and give occupants more time to evacuate.

Features

Common Size

8 feet x 4 feet, 7 feet x 4feet

Common Thickness Range

4mm to 19mm

Key Features of AK Appleply Club — Fire Retardant Plywood

  • Certified to IS 5509 (fire retardant plywood)
  • Core species: Gurjan and Eucalyptus (100% selected hardwood)
  • Adhesive: BWP-grade resin (100 hours BWP performance)
  • CARB Phase 2, E0 emission compliant (low formaldehyde)
  • Double-calibrated Matply technology for consistent thickness and finish
  • 100% core composed, zero-gap construction for structural integrity
  • Stitched core and long-panel core for improved dimensional stability
  • 35-year warranty
  • Resistant to – Borer, Fungal Infestation.

Laboratory Test Report
Ak Apple Ply Club Fire Retardant Plywood (as Per is 5509:2021)

Size: 2440 x 1220 x 19 mm

SL NO TESTS PRESCRIBED VALUE RESULTS
1 Dimensions,mm

a) Length
b) Width
c) Thickness
Tolerance +6mm – 0mm
Tolerance +3mm – 0mm
+/-5%
+2mm
+1mm
+0.8%
2 Squareness, % 0.2 0.06
3 Edge straightness, % 0.2 0.04
4 Workmanship and Finish Conforms Conforms
5 Moisture Content % 5-15 10.4
6 Resistance to water, Adhesion of plies Min. Pass standard Pass Standard
7 Modulus of Elasticity, N/mm²
i) Parallel to the face grain
a) Average
b) Min. Individual
ii) Perpendicular to the Face grain
a) Average
b) Min. Individual
5000
4500

2500
2200
5985
5525

5125
4688
8 Modulus of Rupture, N/mm²
i) Parallel to the Face grain
a) Average
b) Min. Individual
ii) Perpendicular to the Face grain
a) Average
b) Min Individual
40
36

20
18
54
47

44
39
9 Flammability Test Time taken for the second ignition shall not be less than 30 min. 38 min.
10 Flame penetration Time taken for flame penetration shall not be less than 15t/6 min.
Where ‘t’ is the thickness of Plywood
55 Min
11 Rate of burning Time taken to lose weight from 30% to 70% shall not be less than 20 min 35 Min